| Unvented Hot Water
systems give you it all. All the Hot Water you need as fast as you need
it. They operate at Mains pressure so you get your hot water as fast as
you get your cold. |
 |
Because it's pre-heated & stored, (unlike a Combi-boiler) there's lots of it readily available & modern cylinders are so well insulated that you loose next to no heat from them.
Your annual service will:
1. Make sure all of your safety valves are operating correctly. A tundish is provided as an additional safety measure should the relief pipe work become blocked. Water must run to drain without backing up to the tundish for the full test period. |
|
2. It will make sure that all the components fitted are as the manufacturer intended, check that the installation was installed as per building regulations & that it has not been modified out with the manufacturers guidelines.
Manufactures include MegaFlo & FlowMaster |
 |
|
|
| |
| 3.
Check & clean your filter. |
 |
 |
|
| |
 |
|
| |
 |
| The safety valves will
be damaged from any debris entering them so filters are important
to safe operation. |
| These need
to be checked each year. You may not notice a deterioration in performance
as it will happen gradually but a blocked filter will seriously effect
your flow rates & defeat the object of having an unvented cylinder.
|
|
| 4. Check &
re-establish the air-bubble in a bubble top cylinder or pressure check the
expansion vessel & correct as necessary. (Picture top right) |
| |
| The safety features & valves
of this great system is what enables us to benefit from Hot Water at mains
pressure. It does need annual maintenance to ensure optimum safety &
performance. |
| |
| 5. Complete
maintenance records for the system. |
| |
| WARNING: Anyone working on Unvented Hot Water systems in the UK needs to have the current qualifications issued by BPEC. Though entirely safe when installed & serviced by competent engineers, these large vessels contain Hot Water. Mandatory safety valves are provide to make sure that whatever happens, the water cannot boil under pressurised conditions. If these valves are not functioning correctly a very dangerous & explosive set of situations can develop. |